Smart Radiator TRV Installation

Smart Radiator TRV Installation – Any Brand

Your local smart heating service

A properly installed system. A clear handover.

Professional smart radiator TRV installation for room-by-room heating control. Local Gas London checks your radiator valves, fits and pairs compatible smart heads, then tests the setup and shows you how to use it. If a radiator has a manual valve, we can replace the valve body through the separately selected upgrade service. Your postcode-specific options and prices are shown in Booking.

The current Booking choices

Smart TRV services. Choose the number you need.

Select one smart-head installation option, then choose the number of heads in Booking. Add valve-body upgrades only for radiators that need a replacement body. Your local price is calculated after your postcode is checked.

Two counts, one clear plan. For example, five smart heads may need only two valve-body upgrades if the other three radiators already have compatible thermostatic bodies. Choose one of Any Brand, Tado or Hive head installation; the valve upgrade can be added to that choice or booked alone.

Use the − and + quantity controls in Booking to select the work you need. Your local total uses the selected first-item and additional-item rates. Review the full Service Details before you confirm.

A new hub, bridge or boiler thermostat is not included with the tado° or Hive head service unless separately agreed. Compatibility is checked against your existing equipment and product generation.

Room-by-room heating

Warm the rooms you use, when you use them

A smart TRV head opens or closes a compatible thermostatic radiator valve in response to the room setting. A bedroom can follow a different schedule from a living room, without changing the radiator pipework.

The radiator head

The smart device measures temperature and adjusts the valve mechanism. It can be fitted to a suitable existing thermostatic body, sometimes with an approved adapter.

The heating system

Radiator control and boiler control are related but different. Smart heads request boiler heat only when the heating controls support it and are correctly linked. They do not create a new plumbing zone.

Start with compatibility. The radiator valve body, smart head, hub or bridge and boiler controls must support the intended setup. We check the actual model and product family.

Before the smart head can fit

Manual or traditional valve? Check the valve body.

A manual handwheel valve works like a tap. It controls water flow but has no thermostatic mechanism for a smart head to operate. A smart head cannot simply be screwed onto it.

A thermostatic valve body has an operating pin that the head can control. If its connection suits the chosen smart head, the head can be replaced without changing the water-carrying body. A suitable approved adapter may solve a connection mismatch.

Older decorative radiators, bathroom radiators and towel rails may have manual valves. Chrome, brass, copper or black finishes do not tell the whole story: some traditional-looking valves are already thermostatic.

Upgrade to smart TRV compatibility. Our valve-body upgrade supplies and replaces the water-carrying body. Smart heads and their installation are a separately selected service. An adapter cannot convert a manual valve into a thermostatic valve.

The valve upgrade explained

More than a change of radiator head

Opening a water-carrying valve connection needs proper system preparation and testing. The engineer confirms the appropriate isolation and draining method; full heating-system draining is included where required.

Check the radiator, both valves, local pipework, smart-head connection and any required bypass or minimum-flow provision.

Switch off and safely isolate the heating. Drain as required so the water-carrying valve can be removed safely.

Remove the old body and radiator tail where necessary. Supply and install a suitable thermostatic body and standard local fittings.

Cut or adapt local copper pipe and add necessary sections. Use appropriate compression or soldered connections for the installation.

Refill the heating and add a suitable corrosion inhibitor at the correct dose in accordance with manufacturer instructions.

Bleed the radiators, restore operating pressure where applicable, circulate the heating and check connections for leaks and correct operation.

A body ready for your chosen head. After the upgrade, the compatible smart head is installed through the separately selected head-installation service. The number of bodies needing replacement can be lower than the number of smart heads.

What we do

Install, pair, test and hand over

Smart head installation

Clear equipment boundaries

For your own heads, provide compatible devices, correct adapters, batteries and any required hub or bridge. For Hive or tado° supply-and-install work, the selected heads, standard compatible head adapters and batteries are included.

A new hub, bridge or boiler thermostat is not included unless separately agreed. Valve-body replacement and its water-side work are selected separately.

Plan the right work

Count heads and valve bodies separately

Existing compatible radiator valves

Select smart-head installation for the radiators you want to control. A compatible valve may need only the correct adapter, with no body replacement.

Manual or unsuitable valve bodies

Add valve-body upgrades only for the radiators that require them. You can book the upgrade alone or combine it with one smart-head installation option.

Radiator replacement, a full powerflush, extensive pipework, existing faults, new heating zones and specialist decorative finishes are separate work. Finished-surface restoration and paid app subscriptions are not included. Parking charges may apply.

Everyday benefits

More comfort. More control.

Smart controls help you match heating to daily life. The examples below are based on tado° features; other brands and product generations have different capabilities.

Remote control

Adjust your heating from your phone when plans change.

Schedules that fit your day

Set comfortable temperatures for the times you use your home.

Location-based heating

Geofencing uses household phone locations to help manage away periods.

Open Window Detection

Supported devices recognise cooling associated with an open window; available alerts or automation depend on the setup.

Fresh air & indoor comfort

Temperature and humidity information can help you decide when to ventilate. This is guidance, not an air-pollution sensor.

Room-by-room comfort

Compatible radiator heads let different rooms follow different temperatures. Boiler heat requests need supported, correctly linked controls.

Check the exact model and app plan. Basic tado° app control and scheduling are available without a paid plan. Automatic geofencing, advanced open-window actions and some comfort insights can require a separate manufacturer subscription. Product generation, account settings and permissions matter. Installation does not include paid app subscriptions. Savings vary with your home and use; no fixed saving is promised.

Before the visit

Ready for installation

A few useful preparations

Prices for your address

Enter your postcode in our address checker, then review the available installation options, local prices and appointments in Booking. Read the selected Service Details and the full total before you confirm. No VAT charged.

Compatibility is checked for the actual equipment. Different brands and generations are not automatically interchangeable. Any additional work is agreed separately.

Helpful answers

Smart radiator TRV installation: your questions answered

What is a smart radiator TRV?

A smart thermostatic radiator valve head adjusts hot-water flow through a compatible thermostatic valve body to help control that radiator’s room temperature. Supported systems let you set temperatures and schedules in an app. It does not create a separate pipework heating zone.

Can a smart head fit directly onto a manual valve?

No. A manual handwheel valve works like a tap and does not have the thermostatic operating mechanism needed by a smart head. The water-carrying valve body must first be replaced with a suitable thermostatic body.

How can I tell whether my valve is thermostatic?

Many thermostatic heads have numbered temperature settings and sit on a valve body with an operating pin. Manual handwheels often have only on/off or plus/minus markings. Traditional styling is not proof either way: send clear photographs of both radiator valves so we can check the mechanism and connection.

Does a different valve thread always mean replacement?

No. An approved adapter may fit a compatible existing thermostatic valve body. We check the exact thread, operating pin and smart-head model. An adapter cannot turn a manual valve into a thermostatic one.

What does the valve-body upgrade include?

We supply a suitable thermostatic valve body and standard local fittings, safely isolate and drain as required, replace the body, adapt local pipework where necessary, refill with suitable inhibitor, bleed the radiators and check pressure, leaks and operation. The smart head and its installation are selected separately.

Will the whole heating system need draining?

The appropriate isolation and draining method depends on your installation. The upgrade includes full heating-system draining where required, followed by refilling, inhibitor treatment, bleeding and testing. The engineer confirms the method for your system.

Can I upgrade a bathroom radiator or towel rail?

We check the valve type, radiator, connections and system requirements first. Some towel rails and traditional radiators use manual valves; others are already thermostatic. Any radiator needed for the system’s bypass or minimum flow must be considered before adding a closing smart valve.

Can I supply my own smart heads?

Yes. Choose Any Brand installation in Booking and supply compatible heads, correct adapters, batteries and any required hub or bridge. We fit, pair and test the equipment. Compatibility is confirmed for the actual models.

Can Local Gas London supply tado° or Hive heads?

Supply-and-install services are available in Booking. They include the selected heads, standard compatible head adapters and batteries. A new hub, bridge or boiler thermostat is not included unless separately agreed; an appropriate compatible setup must be available.

Will the smart TRV switch my boiler on?

Only when the selected heating controls support radiator heat requests and are correctly linked. A smart head fitted to a radiator does not automatically gain control of the boiler. With an independent central thermostat, heat may only be available while that thermostat calls for it.

Do all radiators need smart heads?

You can start with suitable selected rooms. The engineer checks how those rooms work with your central controls and the heating system’s flow requirements. Fit compatible devices to the radiators you want to control; full-home smart control requires a suitable overall arrangement.

Can different smart-heating brands be mixed?

Do not assume different brands or generations work together. The head, hub or bridge, boiler controls and app must support the intended arrangement. We check the exact product family before installation.

Can I book heads and valve upgrades together?

Yes. Combine one smart-head installation option with the valve-body upgrade where needed. Count smart heads and replacement valve bodies separately: some radiators may accept a head without any body replacement.

What are the benefits of smart radiator control?

Compatible heads let you set different room temperatures and schedules, so a bedroom and living room need not follow the same setting. Supported tado° features can also help manage away periods and open-window heating. Availability and automation depend on the devices, setup and app plan.

What should I prepare before installation?

Provide access to each radiator, your app account and the required internet connection. Tell us the existing smart-heating brand and generation. For valve upgrades, send photographs of both valves and the local pipework. For customer-supplied heads, have the correct adapters, batteries and hub ready.

Where do I find prices and appointments?

Enter your postcode in Booking to see the applicable local prices and available appointments. Select the number of smart heads and, if needed, the number of valve-body upgrades. Review the service details and full total before confirming. No VAT charged.

Does valve replacement include a powerflush or new radiator?

No. The upgrade covers the specified valve bodies and necessary local work. A full powerflush, radiator replacement, extensive pipework, existing-system repairs and specialist decorative finishes are separate services or separately agreed work.

Your next step

Find smart radiator installation for your address

Confirm your postcode, choose the smart-head installation and any required valve-body upgrades, then review your Service Details and total in Booking.

Manufacturers

  • Worcester Bosch
  • Vaillant
  • Viessmann
  • Ideal Heating
  • Baxi
  • Glow-worm